Maxron R-404A is a hydrofluorocarbon (HFC) refrigerant blend designed for low and medium temperature refrigeration systems. It’s made up of R-125 (44%), R-143a (52%), and R-134a (4%), and is a non-ozone depleting substitute for the older R-502 refrigerant.

In Kenya, Olinc Industrial Products & Equipment Ltd is a leading authorized distributor of Maxron refrigerant gases, offering quality, genuine products with full safety documentation, technical support, and fast nationwide delivery.

Maxron R-404A is also commonly referred to as R404A, and both names describe the same refrigerant gas.

Applications of Maxron R-404A

Maxron R-404A is widely used in commercial and industrial refrigeration systems that require reliable cooling performance in low and medium temperature environments, such as:

  • Cold Rooms & Freezers
  • Food Processing Plants
  • Refrigerated Trucks & Transport Systems
  • Supermarket Display Cabinets & Ice Cream Machines
  • Ice Makers & Blast Freezers
  • Meat, Dairy, and Seafood Storage Facilities

Its excellent thermodynamic properties make it ideal for both new installations and retrofit projects from older refrigerants like R-502.

Technical Specifications

PropertySpecification
Chemical CompositionR-125 (44%), R-143a (52%), R-134a (4%)
TypeHFC Blend
ASHRAE Safety ClassA1 – Non-flammable, Low Toxicity
Boiling Point (1 atm)−46.5 °C
Critical Temperature72.1 °C
Critical Pressure37.3 bar
Ozone Depletion Potential (ODP)0
Global Warming Potential (GWP)≈ 3,922
Recommended LubricantPOE (Polyolester) Oil
Cylinder Sizes3.4 kg, 6.8 kg, 13.6 kg, and disposable options
AppearanceClear, colorless, liquefied gas
OdorSlight ether-like smell

Advantages of Maxron R-404A

  •  Excellent cooling efficiency for both low & medium temperature applications
  •  Non-ozone depleting (ODP = 0)
  •  Stable, non-flammable, and safe when handled properly
  •  Compatible with most existing R-502 equipment (with retrofit)
  •  Proven performance in food, transport, and commercial refrigeration
  •  Reliable thermodynamic performance under Kenyan climatic conditions

Is Maxron R-404A the Same as R-404A?

Yes — Maxron R-404A is the brand name under which the R-404A refrigerant gas is sold. Chemically, they are identical. “R-404A” is the international ASHRAE designation for the blend, while “Maxron” is a trusted brand known for high-purity gases, reliability, and excellent performance.

Environmental Impact

  • Zero Ozone Depletion Potential (ODP = 0) — safe for the ozone layer.
  • High Global Warming Potential (GWP ≈ 3922) — requires responsible handling to minimize emissions.
  • Recover, recycle, or reclaim refrigerant to avoid environmental release.
  • Kenya, as part of the Kigali Amendment, encourages gradual transition to lower-GWP alternatives such as R-452A or R-448A.

Olinc promotes eco-friendly refrigerant use, offering recovery equipment and trained technicians for sustainable cooling.

Handling, Safety & Storage Guidelines

    Handling Precautions

  • Use protective gloves, goggles, and overalls during charging or maintenance.
  • Avoid contact with liquid refrigerant (can cause frostbite).
  • Ensure proper ventilation during servicing — refrigerant displaces oxygen.
  • Never heat cylinders or expose to open flames.
  • Use accurate leak detectors to monitor system integrity.

   Storage Guidelines

  • Store cylinders upright in a cool, dry, and well-ventilated area.
  • Keep away from direct sunlight, heat sources, or open flames.
  • Do not store above 50°C.
  • Keep valve caps in place when not in use.
  • Rotate stock regularly using the FIFO system (First In, First Out).

    Maintenance Tips

  • Check system pressures and temperatures routinely.
  • Replace filter driers after servicing.
  • Conduct leak tests before recharging systems.Use POE lubricants only — avoid mixing oils.
  • Always recover refrigerant during service or decommissioning.

Compatibility & Retrofit Information

Maxron R-404A can replace R-502 in existing systems after proper retrofitting.
Steps include:

  • Drain and replace oil with POE oil
  • Replace filter drier
  • Check seals and gaskets for HFC compatibility
  • Recalibrate expansion valves if necessary
  • Charge system by liquid phase (to maintain blend consistency)

Olinc Industrial provides technical guidance and retrofit support to ensure safe conversions.

Why Choose Olinc Industrial Products & Equipment Ltd

  • Authorized distributor of Maxron Refrigerants in Kenya
  •  Supplies complete refrigeration solutions — gases, copper pipes, compressors, insulation, and tools
  •  Offers technical support, MSDS sheets, and training
  •  Provides fast delivery within Nairobi and across East Africa
  •  Guarantees quality, certified cylinders, and competitive pricing

With years of industry experience, Olinc is trusted by refrigeration engineers, cold room installers, and HVAC technicians across Kenya.

Definition

Maxron R-404A is a non-ozone depleting refrigerant gas composed of three HFC components:

  • R-125 (44%)
  • R-143a (52%)
  • R-134a (4%)

It is sold under the brand name “Maxron”, and in Kenya it’s distributed by Olinc Industrial Products & Equipment Ltd — a leading supplier of refrigeration gases and insulation materials.

The refrigerant is often labeled as R-404A, R404A, or Maxron R-404A — all refer to the same chemical blend.

Purpose & Application

Maxron R-404A is specially formulated for:

  • Low temperature refrigeration (−45 °C to −20 °C)
  • Medium temperature refrigeration (−15 °C to +10 °C)

Typical uses include:

  • Commercial & industrial cold rooms
  • Supermarket freezers and display cabinets
  • Ice makers and blast freezers
  • Transport refrigeration (reefers, refrigerated trucks)
  • Food processing & preservation equipment

It’s commonly used as a replacement for R-502, which was phased out for ozone protection reasons.

Contact Olinc Industrial

Olinc Industrial Products & Equipment Ltd
Nairobi, Kenya
                +254 722 830 970
                 www.olincindustrial.com
                 info@olincindustrial.com